Precautionary statement · Response

What does P371 mean?

In case of major fire and large quantities:

Group
Response (P3xx)
Status
In SEA Annex 4 list

What kind of precautionary statement is P371?

Response statements (P3xx) say what to do after an accident, spill, fire or exposure: first-aid steps, rinsing and washing, calling a doctor or a poison centre, choosing the extinguishing medium. They usually open with a situation such as IF IN EYES or IF INHALED.

Which hazards is it used for?

In the CLP Annex IV assignment table used by Chemoris, P371 is not linked directly to a class; it is used as part of a combined statement or at the supplier's choice.

Combined statements containing this code

Neighbouring statements of the same kind

The statements closest in number to P371 in the response group:

  • P363Wash contaminated clothing before reuse.
  • P364And wash it before reuse.
  • P370In case of fire:
  • P372Explosion risk.
  • P373DO NOT fight fire when fire reaches explosives.
  • P374Fight fire with normal precautions from a reasonable distance.

How is P371 read?

This statement is a 8-word text. The text only names the situation "In case of major fire and large quantities"; the instruction itself is completed in the codes that combine with this statement (see the combined statements below).

Where is P371 written in the SDS?

If P371 is on the list of precautionary statements in Section 2.2, it is printed with its code and the text "In case of major fire and large quantities:". The statement should also agree with the firefighting measures in Section 5.

How does P371 appear on the label?

P371 shows up on a label only if it is selected: the candidates from Annex IV are reduced to at most 6 under Article 28(3). In the Chemoris selection method, response statements are considered in position 1. If the core statements exceed 6, Article 28(3) allows up to 8; when a combined statement is chosen, its individual parts are not repeated on the label. As P371 is on the list of precautionary statements of Annex IV, it can be used in current labels and SDSs; Chemoris writes it into the document only when the relevant response candidate is selected.

Which classes and which priority is P371 assigned to?

Related assignment entries: 2 class/category entries, 1 different H statements. Priority split: secondary (priority 2) in 2 entries. Of these entries, 2 carry the signal word “Danger”, 0 carry “Warning” and 0 need no signal word. The pictograms that most often accompany it: GHS03 (2).

The class families it appears in most often: Ox. Liq. (1) and Ox. Sol. (1).

Classes that P371 is assigned to

P371 is not assigned to a class on its own; the combined statements it belongs to (P371+P380+P375) are assigned to these classes:

ClassH codeAssignment typePriorityAssigned as
Ox. Liq. 1—responsesecondaryP371+P380+P375
Ox. Sol. 1—responsesecondaryP371+P380+P375

Where does P371 stand in the response group?

P371 is number 41 of the 82 statements in the P3xx group. The group holds 30 combined and 11 withdrawn statements and 46 single valid statements. Combined statements merge several situations on one line; withdrawn statements are replaced by their current equivalents.

Which SDS section does P371 feed?

Because of its number and its response kind, P371 relates to Section 5 Firefighting of the SDS; in Section 2.2 it is written with its code and text. Statements in the same number range feed the same section.

Checklist when writing P371

  • P371 is a part of the combined statements P371+P380+P375; when a combined statement is selected, P371 is not repeated on the label.
  • P371 should agree with Section 5; in Section 2.2 it is written with its code and text.
  • The text is 8 words long; if the label space is narrow, choosing a combined statement can save room.

Official EU wording of P371 in other languages

When a product is exported to the EU, the SDS and label are expected in the official language of the Member State where it is placed on the market (REACH Article 31(5)). The table gives the official wording of P371 from the CLP Annex III/IV language versions published in the Official Journal of the European Union. Source: EUR-Lex CELEX 02008R1272-20260701.

LanguageOfficial wording
GermanBei Großbrand und großen Mengen:
FrenchEn cas d’incendie important et s’il s’agit de grandes quantités:
SpanishEn caso de incendio importante y en grandes cantidades:
ItalianIn caso di incendio grave e di quantità rilevanti:
PolishW przypadku poważnego pożaru i dużych ilości:
DutchIn geval van grote brand en grote hoeveelheden:
PortugueseEm caso de incêndio importante e de grandes quantidades:
RomanianÎn caz de incendiu de proporții și de cantități mari de produs:

Next steps

To read a statement like P371 correctly on a label and in an SDS, see the guide How to read H and P codes; to pick the class and prepare the label automatically, use the free label tool.

Where does it appear in the safety data sheet?

Precautionary statements are given with their code and full text in Section 2.2 (label elements) of the safety data sheet. Alternatives separated by a slash or in square brackets (e.g. gloves/protective clothing) are narrowed down to suit the product.

Frequently asked questions

What kind of precautionary statement is P371?

P371 belongs to the response group (P3xx). Statements of the response kind sit in the precautionary part of the label.

Source: Regulation (EC) No 1272/2008 (CLP) Annex IV; Turkish SEA Regulation (Official Gazette 28848) Annex 4. The statement is the official English text of CLP Annex IV. Updated: 6 November 2026.