Hazard statement · Physical hazards
What does H271 mean?
May cause fire or explosion; strong oxidiser.
- Hazard class
- Oxidising Liquids, Hazard Category 1; Oxidising Solids, Hazard Category 1 (Ox. Liq. 1 / Ox. Sol. 1)
- Pictogram
GHS03Flame over circle- Signal word
- Danger
Categories and label elements
| CLP abbreviation | Pictogram | Signal word |
|---|---|---|
| Ox. Liq. 1 | Danger | |
| Ox. Sol. 1 | Danger |
Related precautionary statements (P codes)
The precautionary statements that CLP Annex IV assigns to this class. Not all of them go on the label: under CLP Article 28(3), no more than six precautionary statements appear on the label unless the nature and severity of the hazard require more; the selection depends on the product and its users.
Prevention
Response
- P306+P360IF ON CLOTHING: rinse immediately contaminated clothing and skin with plenty of water before removing clothes.
- P371+P380+P375In case of major fire and large quantities: Evacuate area. Fight fire remotely due to the risk of explosion.
- P370+P378In case of fire: Use… to extinguish.
Disposal
- P501Dispose of contents/container to …
Build a label with this class. The free label tool works out the pictogram, the signal word and the P statements for the label from the classes you choose.
Where is H271 written in the SDS?
H271 is tracked in three places of the SDS: the classification line in Section 2.1 ("Ox. Liq. 1 / Ox. Sol. 1"), the label elements in Section 2.2 and the component list in Section 3. Section 16 repeats the explanation of the code. In addition, it must agree with the physical and chemical properties in Section 9 and, if the product is subject to transport rules, it is read together with the ADR information in Section 14.
How does H271 appear on the label?
The label elements for H271 are: pictogram GHS03 (flame over circle); it is written with the signal word "Danger". In the Chemoris template Section 2.2 carries at most 8 H statements; if the limit is exceeded the least severe ones are dropped and a warning is shown. For the bottom of the label, 8 P statements are candidates for this class in CLP Annex IV; under CLP Article 28 at most 6 of them are selected.
Where does it appear in the safety data sheet?
- Section 2.1: classification; the class abbreviation and H271 are given together.
- Section 2.2: label elements; H271 with its full text, pictogram and signal word.
- Section 3: composition table; in the row of every component that has this class.
- Section 16: the full text of the H statements cited as codes in earlier sections.
Class criteria and thresholds for H271
The values below come from the Chemoris rule file (CLP Annex I). They show the condition under which H271 arises in a mixture. For physical hazards and other classes that depend on test data, the result comes from the mixture's own measurement, not from component percentages.
The class behind H271 depends on the mixture's own test data; the Chemoris rule file does not derive it from component percentages and warns the chemist when a component carries it (≥ 1 %) (CLP Annex I 2.x (for physical hazards 1.1.1.3 / Article 6(5) data requirement); 2.16.3 (metal-corrosive mixture)).
H271 compared with H272 and H270
The table below puts H271 next to its closest neighbouring statements; the values are read from the rule data.
| Hazard statement | H271 | H272 | H270 |
|---|---|---|---|
| Class abbreviation | Ox. Liq. 1 / Ox. Sol. 1 | Ox. Liq. 2 / Ox. Sol. 2 | Ox. Gas 1 |
| Pictogram | GHS03 | GHS03 | GHS03 |
| Signal word | Danger | Danger | Danger |
| Precautionary statements assigned | 8 | 5 | 4 |
| Concentration cut-off in a mixture | — | — | — |
H271 and H272 carry the same signal word (Danger). Both are shown with the same pictogram (GHS03). H271 and H270 carry the same signal word (Danger). Both are shown with the same pictogram (GHS03).
In which SDS sections does H271 appear?
H271 does not stay only in the label section of an SDS; the class itself and the precautionary statements assigned to it shape the content of other sections too. The counts are calculated from the P statements that Annex IV assigns to this class.
| SDS section | Relation to this code |
|---|---|
| 2.1 Classification | Written with the abbreviation Ox. Liq. 1 / Ox. Sol. 1 and the code H271. |
| 2.2 Label elements | H271 appears with its full text, GHS03 (flame over circle) and “Danger”. |
| 3 Composition | The class and code show in the row of every component that carries this class. |
| 9 Physical and chemical properties | The classification has to agree with properties such as flash and boiling point given here. |
| 4 First aid | Of the 8 assigned P statements, 1 belong to the subject of this section: P306+P360. |
| 5 Firefighting | Of the 8 assigned P statements, 2 belong to the subject of this section: P371+P380+P375, P370+P378. |
| 7 Handling and storage | Of the 8 assigned P statements, 2 belong to the subject of this section: P210, P220. |
| 8 Exposure controls / PPE | Of the 8 assigned P statements, 2 belong to the subject of this section: P280, P283. |
| 13 Disposal | Of the 8 assigned P statements, 1 belong to the subject of this section: P501. |
| 14 Transport | ADR mapping: Class 5.1, packing group I; ADR 2.2.51.1.7. |
| 16 Other information | The full text of the H statements cited by code is collected here. |
Statements that appear on the label together with H271
H271 is never printed alone on a label; it sits next to the pictogram and the signal word. The Chemoris selection method (response, prevention, storage, disposal in that order; core statements first) gives these first 5 candidates for this class:
(Ox. Liq. 1)
| Rank | P code | Type | Priority | Text |
|---|---|---|---|---|
| 1 | P306+P360 | response | core | IF ON CLOTHING: rinse immediately contaminated clothing and skin with plenty of water before removing clothes. |
| 2 | P371+P380+P375 | response | core | In case of major fire and large quantities: Evacuate area. Fight fire remotely due to the risk of explosion. |
| 3 | P370+P378 | response | core | In case of fire: Use… to extinguish. |
| 4 | P210 | prevention | core | Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. |
| 5 | P220 | prevention | core | Keep away from clothing and other combustible materials. |
The GHS03 pictogram and “Danger” are printed together. This ranking applies because a label usually carries at most 6 statements; when a combined statement is selected, its parts are not printed again.
Official EU wording of H271 in other languages
When a product is exported to the EU, the SDS and label are expected in the official language of the Member State where it is placed on the market (REACH Article 31(5)). The table gives the official wording of H271 from the CLP Annex III/IV language versions published in the Official Journal of the European Union. Source: EUR-Lex CELEX 02008R1272-20260701.
| Language | Official wording | Class title | Signal word |
|---|---|---|---|
| German | Kann Brand oder Explosion verursachen; starkes Oxidationsmittel. | Oxidierende Flüssigkeiten, Gefahrenkategorie 1; Oxidierende Feststoffe, Gefahrenkategorie 1 | Gefahr |
| French | Peut provoquer un incendie ou une explosion; comburant puissant. | Liquides comburants, catégorie de danger 1; Matières solides comburantes, catégorie de danger 1 | Danger |
| Spanish | Puede provocar un incendio o una explosión; muy comburente. | Líquidos comburentes, categoría 1; Sólidos comburentes, categoría 1 | Peligro |
| Italian | Può provocare un incendio o un'esplosione; molto comburente. | Liquidi comburenti, categoria di pericolo 1; Solidi comburenti, categoria di pericolo 1 | Pericolo |
| Polish | Może spowodować pożar lub wybuch; silny utleniacz. | Substancje ciekłe utleniające, kategoria zagrożenia 1; Substancje stałe utleniające, kategoria zagrożenia 1 | Niebezpieczeństwo |
| Dutch | Kan brand of ontploffingen veroorzaken; sterk oxiderend. | Oxiderende vloeistoffen, gevarencategorie 1; Oxiderende vaste stoffen, gevarencategorie 1 | Gevaar |
| Portuguese | Risco de incêndio ou de explosão; muito comburente. | Líquidos comburentes, categoria de perigo 1; Sólidos comburentes, categoria de perigo 1 | Perigo |
| Romanian | Poate provoca un incendiu sau o explozie; oxidant puternic. | Lichide oxidante, categoria de pericol 1; Solide oxidante, categoria de pericol 1 | Pericol |
Common mistakes with H271
- Deriving the class from percentages: H271 cannot be calculated from component percentages; the mixture's own test data is required (CLP Annex I 2.x (for physical hazards 1.1.1.3 / Article 6(5) data requirement); 2.16.3 (metal-corrosive mixture)).
- Pouring every P candidate onto the label: there are 8 candidates, but CLP Article 28(3) limits a label to 6 precautionary statements (up to 8 when needed).
- Writing unlimited H statements for a multi-class product: in the Chemoris template, Section 2.2 holds at most 8 H statements.
Next steps
To read a statement like H271 correctly on a label and in an SDS, see the guide How to read H and P codes; to pick the class and prepare the label automatically, use the free label tool.
Related hazard statements
Other H statements in the same hazard family as H271 (Ox. Liq. / Ox. Sol.). The difference between categories mostly comes from the degree of severity.
- H272May intensify fire; oxidiser.
Frequently asked questions
Which pictogram and signal word go with H271 on a label?
For H271 the pictogram is GHS03 (flame over circle); it is written with the signal word "Danger".
How many P statements does H271 need?
CLP Annex IV assigns 8 precautionary statements to the class of H271, but under CLP Article 28(3) a label usually carries at most 6 of them; the selection depends on the product and its user.
In which SDS sections does H271 appear?
H271 appears in Sections 2.1 (classification), 2.2 (label), 3 (composition) and 16, and also in 9, 4, 5, 7, 8, 13 and 14.
What is the difference between H271 and H272?
H271 carries Danger and GHS03; H272 carries Danger and GHS03.
Source: Regulation (EC) No 1272/2008 (CLP) Annexes I and III; Turkish SEA Regulation (Official Gazette 28848). The statement is the official English text of CLP Annex III. Pictogram and signal word: CLP Annex I Table 2.13.2 · CLP Annex I Table 2.14.2. Updated: 6 November 2026.