Precautionary statement · Storage
What does P410+P412 mean?
Protect from sunlight. Do no expose to temperatures exceeding 50 o C/122 o F.
- Group
- Storage (P4xx)
- Status
- In SEA Annex 4 list
What kind of precautionary statement is P410+P412?
Storage statements (P4xx) set the conditions for keeping the product safely: locked up, in a cool, well-ventilated place or in the original container, protected from sunlight. Warehouse layout and container choice follow from these statements.
Which hazards is it used for?
In the CLP Annex IV assignment table, P410+P412 is assigned to the classes of these hazard statements:
Parts of the combined statement
How many hazard statements is P410+P412 assigned to?
In the CLP Annex IV assignment table, P410+P412 is provided for the classes of 2 H statements in total: 2 physical hazard statements. The lowest-numbered example is H222 and the highest-numbered is H223. Whether a mixture label carries this statement depends on those classes really applying to the mixture.
Neighbouring statements of the same kind
The statements closest in number to P410+P412 in the storage group:
How is P410+P412 read?
The length of P410+P412 is 14 words. It contains options separated by a slash; the preparer keeps the option that fits the product and deletes the others. Because it is a combined statement, it replaces 2 separate statements in a single line; the parts are listed below.
Where is P410+P412 written in the SDS?
When you prepare an SDS, P410+P412 goes into Section 2.2; options in the text (slashes or square brackets) are narrowed down to the product before it is written. The statement should also agree with the safe storage conditions in Section 7.2.
How does P410+P412 appear on the label?
The classes and the use of the product decide whether it reaches the label; not all candidates are written, at most 6 statements remain. In the Chemoris selection method, storage statements are considered in position 3. If the core statements exceed 6, Article 28(3) allows up to 8; when a combined statement is chosen, its individual parts are not repeated on the label. As P410+P412 is on the list of precautionary statements of Annex IV, it can be used in current labels and SDSs; Chemoris writes it into the document only when the relevant storage candidate is selected.
Which classes and which priority is P410+P412 assigned to?
In the CLP Annex IV assignment table, P410+P412 appears in 1 class/category entries (1 different H statements). Priority split: core (priority 1) in 1 entries. Of these entries, 0 carry the signal word “Danger”, 0 carry “Warning” and 1 need no signal word.
The class families it appears in most often: Aerosol * (1).
Classes that P410+P412 is assigned to
The first 1 rows of 1 entries in the CLP Annex IV assignment table (by priority and hazard order):
| Class | H code | Assignment type | Priority |
|---|---|---|---|
| Aerosol * | — | storage | core |
Statements assigned together with P410+P412
The precautionary statements that most often appear with P410+P412 in the same class entries (with entry count):
- P210Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. (1)
- P211Do not spray on an open flame or other ignition source. (1)
- P251Do not pierce or burn, even after use. (1)
- P410+P412Protect from sunlight. Do no expose to temperatures exceeding 50 o C/122 o F. (1)
Where does P410+P412 stand in the storage group?
P410+P412 is number 18 of the 19 statements in the P4xx group. The group holds 6 combined and 2 withdrawn statements and 12 single valid statements. Combined statements merge several situations on one line; withdrawn statements are replaced by their current equivalents.
Which SDS section does P410+P412 feed?
Because of its number and its storage kind, P410+P412 relates to Section 7 Handling and storage of the SDS; in Section 2.2 it is written with its code and text. Statements in the same number range feed the same section.
Checklist when writing P410+P412
- The text contains options separated by a slash; the preparer keeps only the option that fits the product.
- P410+P412 should agree with Section 7; in Section 2.2 it is written with its code and text.
- The text is 14 words long; if the label space is narrow, choosing a combined statement can save room.
Official EU wording of P410+P412 in other languages
When a product is exported to the EU, the SDS and label are expected in the official language of the Member State where it is placed on the market (REACH Article 31(5)). The table gives the official wording of P410+P412 from the CLP Annex III/IV language versions published in the Official Journal of the European Union. Source: EUR-Lex CELEX 02008R1272-20260701.
| Language | Official wording |
|---|---|
| German | Vor Sonnenbestrahlung schützen und nicht Temperaturen über 50 o C/122 o F aussetzen. |
| French | Protéger du rayonnement solaire. Ne pas exposer à une température supérieure à 50 o C/122 o F. |
| Spanish | Proteger de la luz del sol. No exponer a temperaturas superiores a 50 o C/122 o F. |
| Italian | Proteggere dai raggi solari. Non esporre a temperature superiori a 50 o C/122 o F. |
| Polish | Chronić przed światłem słonecznym. Nie wystawiać na działanie temperatury przekraczającej 50 o C/122 o F. |
| Dutch | Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 o C/122 o F. |
| Portuguese | Manter ao abrigo da luz solar. Não expor a temperaturas superiores a 50 o C/122 o F. |
| Romanian | A se proteja de lumina solară. Nu expuneți la temperaturi care depășesc 50 o C/122 o F. |
Next steps
To read a statement like P410+P412 correctly on a label and in an SDS, see the guide How to read H and P codes; to pick the class and prepare the label automatically, use the free label tool.
Where does it appear in the safety data sheet?
Precautionary statements are given with their code and full text in Section 2.2 (label elements) of the safety data sheet. Alternatives separated by a slash or in square brackets (e.g. gloves/protective clothing) are narrowed down to suit the product.
Frequently asked questions
What kind of precautionary statement is P410+P412?
P410+P412 belongs to the storage group (P4xx). Statements of the storage kind sit in the precautionary part of the label.
Is P410+P412 mandatory on a label?
Not by itself: P410+P412 is provided for the classes of 2 H statements and is a candidate only if the product falls into one of those classes. Under Article 28(3) the candidates are usually reduced to at most 6.
Which statements does P410+P412 consist of?
P410: Protect from sunlight. P412: Do not expose to temperatures exceeding 50 o C/122 o F.
Which statements appear with P410+P412 on a label?
The statements that most often accompany it in the same class entries are P210, P211, P251 and P410+P412.
Which hazard classes use P410+P412?
According to CLP Annex IV it appears in 1 class entries; the most frequent class families are Aerosol * (1).
Source: Regulation (EC) No 1272/2008 (CLP) Annex IV; Turkish SEA Regulation (Official Gazette 28848) Annex 4. The statement is the official English text of CLP Annex IV. Updated: 6 November 2026.
Prepare your SDS